Klinika JL — Magnetická rezonance
About
Specialties
- Price range
- Kč 4,000–Kč 15,000
- Treatments
- 17
- Locations
- 1
- Languages
- 8
Treatments
17 treatments
brain-mri
MRI Brain with Angiography (MR mozku vč. angiografie)
MRI Brain with Angiography combines a standard brain parenchyma study with MR angiography (MRA) in a single session on Klinika JL's Philips 3 Tesla scanner. MRA maps the intracranial arteries and veins without the need for arterial catheterisation, showing the calibre, course and wall integrity of the cerebral vessels. This combined protocol is the first-line investigation for suspected aneurysm, arteriovenous malformation, carotid stenosis and other cerebrovascular conditions where the anatomy of both brain tissue and its blood supply needs to be assessed together. Gadolinium contrast is required. The clinic runs seven days a week until 21:00, allowing prompt imaging when a vascular referral is urgent.
mri
MRI Fetus (MR plodu)
Fetal MRI (MR plodu) at Klinika JL is a specialised obstetric imaging study performed after 12 weeks gestation to evaluate fetal anatomy in cases where ultrasound is inconclusive — most commonly for central nervous system anomalies (ventriculomegaly, corpus callosum agenesis, cortical malformations), lung masses, diaphragmatic hernia and abdominal organ anomalies. At 15,000 Kč self-pay it is the most complex and highest-priced study on the clinic's list. No contrast is used. The Philips 3 Tesla scanner acquires rapid sequences designed to freeze fetal motion. The clinic requires a full bladder at the time of scan and a referral from a maternal-fetal medicine specialist or obstetrician.
pelvis-mri
MRI Prostate — Multiparametric (MR prostaty)
Multiparametric prostate MRI (mpMRI) at Klinika JL is the gold-standard imaging investigation for prostate cancer detection and staging, performed on the Philips 3 Tesla scanner with gadolinium contrast. The exam combines T2-weighted anatomical sequences, diffusion-weighted imaging (DWI) and dynamic contrast-enhanced (DCE) sequences to assign a PI-RADS score (1–5) to any suspicious lesion — guiding the decision between surveillance, targeted biopsy and treatment. At 3 Tesla without an endorectal coil, image quality is sufficient for PI-RADS scoring in most patients. Self-pay price is 9,000 Kč plus contrast. The clinic is open daily until 21:00 for urgent urology referrals.
mri
MRI Placenta (MR placenty)
MRI placenta study at Klinika JL is an obstetric imaging exam performed after 12 weeks gestation when ultrasound findings are inconclusive or when placenta accreta spectrum (PAS) is suspected — particularly in women with a previous caesarean section and anterior low placenta. No contrast agent or ionising radiation is used; the Philips 3 Tesla scanner provides the tissue contrast needed to assess placental attachment depth, uterine wall integrity and bladder involvement. A full bladder at the time of the scan improves delineation of the lower uterine segment. This is one of the most specialised obstetric imaging services available at a private outpatient MRI centre in Prague.
brain-mri
MRI Brain (MR mozku)
A 3 Tesla MRI brain scan at Klinika JL delivers detailed images of brain tissue, blood vessels, the pituitary gland, visual and auditory pathways in a single session using Philips high-field technology. The scan uses gadolinium contrast agent administered intravenously, which highlights abnormal areas including tumours, inflammations and vascular malformations that would be difficult to detect on a native scan. Klinika JL operates seven days a week from 07:00 to 21:00 — booking within days rather than the weeks-long waits common at hospital radiology departments. Referrals from any doctor, including foreign physicians, are accepted for self-pay patients. Findings are reported by a qualified radiologist and shared digitally within 14 days; images transfer free via ePACS or Redimed networks.
abdomen-mri
MRI Liver (MR jater)
Liver MRI at Klinika JL uses the Philips 3 Tesla scanner with gadolinium contrast to provide definitive characterisation of liver lesions — distinguishing benign haemangiomas, focal nodular hyperplasia and adenomas from hepatocellular carcinoma and metastases in a way that ultrasound and CT cannot reliably achieve. Dynamic contrast sequences capture arterial, portal venous and delayed phases of enhancement, which are the hallmark pattern that identifies HCC. 3 Tesla field strength enables diffusion-weighted imaging (DWI) that adds functional information about cell density. Self-pay patients pay 9,000 Kč plus contrast. Three-to-four hour fasting before the scan reduces bowel motion artefact.
mri
MRI Neck Soft Tissues (MR krku)
MRI of the neck at Klinika JL images the cervical soft tissues, salivary glands, lymph nodes and vessels using the Philips 3 Tesla scanner with gadolinium contrast, providing fine-detail assessment that ultrasound and CT cannot always match. The high field strength resolves small lymph nodes below the submandibular glands, parotid lesions and subtle infiltration of the pre-vertebral fascia — critical staging information for ENT oncology. Self-pay patients pay 9,000 Kč plus 2,000 Kč for contrast. Open daily 07:00–21:00, the clinic can accommodate urgent head-and-neck oncology referrals that require imaging before the next MDT meeting.
joint-mri
MRI Small and Medium Joint — Wrist, Elbow or Ankle (MR zápěstí / loket / hlezno)
Klinika JL offers 3 Tesla MRI of the wrist, elbow or ankle — three commonly injured joints where soft-tissue detail is essential for surgical planning. The Philips 3 Tesla scanner resolves the fine ligaments of the wrist (TFCC, scapholunate and lunotriquetral), the lateral and medial elbow compartments, and the ankle lateral and medial ligament complexes and tendons. Each booking covers one joint at 9,000 Kč. The scanner bore accommodates studies in natural limb position; the wide-bore 70 cm Ingenia option provides additional patient comfort when joint positioning requires an unusual arm posture.
abdomen-mri
MRI Liver — Targeted Contrast Study (MR cílené zobrazení jater)
The targeted contrast liver study at Klinika JL is a focused MRI protocol that emphasises contrast-enhanced sequences for monitoring a known liver lesion or following up a specific area after prior imaging. At 4,000 Kč self-pay with contrast included, it is the lowest-priced MRI on the clinic's list and suited to surveillance protocols where a full multi-phase study has already been performed. Fasting for 3–4 hours is required. The Philips 3 Tesla scanner provides the same field strength as the full liver study; this shorter protocol completes the imaging task efficiently without repeating the full dynamic workup.
abdomen-mri
MRI Enterography — Small Bowel (MR enterografie)
MRI enterography (MR enterografie) at Klinika JL is the investigation of choice for small bowel imaging in Crohn's disease, providing comprehensive cross-sectional views of bowel wall thickness, enhancement pattern, mesenteric inflammation and fistula formation without radiation exposure — a critical advantage given the young age of many Crohn's patients. The 90-minute pre-scan oral contrast preparation (a large volume of polyethylene glycol or mannitol solution) distends the small bowel so the wall can be assessed in full. Gadolinium contrast is given intravenously during the scan. Total appointment time is 2–3 hours.
joint-mri
MRI Shoulder (MR ramene)
Shoulder MRI at Klinika JL examines the rotator cuff, labrum, acromioclavicular joint, biceps tendon and surrounding bursae in one session on the Philips 3 Tesla scanner, without ionising radiation. Partial and full-thickness rotator cuff tears, superior labral lesions (SLAP tears), bankart lesions and subacromial impingement are reliably distinguished at 3 Tesla field strength, giving orthopaedic surgeons the anatomical detail they need before arthroscopy or repair. Self-pay price is 8,000 Kč for one shoulder. The clinic's daily 07:00–21:00 hours allow evening appointments around a sports season or pre-operative schedule.
joint-mri
MRI Knee (MR kolene)
Knee MRI at Klinika JL evaluates the menisci, cruciate ligaments, collateral ligaments, articular cartilage and joint effusion in a single 20–40 minute session on the Philips 3 Tesla scanner. Meniscal tears, ACL and PCL injuries, cartilage defects and bone marrow oedema are shown with a clarity that drives surgical planning for arthroscopy. The 3 Tesla field strength improves cartilage-to-fluid contrast and enables thin-slice acquisitions of the patellofemoral joint and tibial plateau surfaces. Self-pay price is 8,000 Kč per knee, and the clinic's seven-days-a-week schedule accommodates weekend sports injuries.
joint-mri
MRI Hip and Limb Segments (MR kyčelních kloubů / stehna / bérce / paže / předloktí)
Klinika JL performs 3 Tesla MRI of the hip joints and major limb segments — thigh, lower leg, upper arm and forearm — covering the muscles, tendons, fascia and bone marrow of each region. The wide-bore 70 cm Philips Ingenia is available for hip and limb studies where patient size or positioning benefit from extra space. At 9,000 Kč per region, these exams are used by orthopaedic and sports medicine teams to characterise soft-tissue tumours, muscle tears, stress reactions, avascular necrosis of the femoral head, and hip impingement syndromes before surgical intervention.
pelvis-mri
MRI Pelvis (MR pánve)
Pelvic MRI at Klinika JL examines the bladder, uterus, ovaries, fallopian tubes, pelvic floor, rectum and lymph nodes in a single radiation-free session on the Philips 3 Tesla scanner. For gynaecological oncology, MRI staging of endometrial and cervical carcinoma is the gold standard — high-resolution T2 images show myometrial invasion depth and parametrial extension with far greater accuracy than ultrasound or CT. For urology, bladder lesion staging and pelvic floor assessment are also covered. Three-to-four hour fasting reduces bowel motion artefact. Self-pay price is 9,000 Kč plus contrast.
brain-mri
MRI Epilepsy Protocol (MR epileptický protokol)
The MRI epilepsy protocol at Klinika JL is a dedicated high-resolution neuroimaging study optimised to detect structural causes of seizure disorders — cortical dysplasias, hippocampal sclerosis, low-grade tumours and other subtle lesions that standard brain MRI sequences may miss. The Philips 3 Tesla scanner acquires thin-slice coronal sequences through the temporal lobes at the orientation best suited to the hippocampus, plus high-resolution volumetric data enabling 3D reconstruction. A fixed self-pay price of 12,000 Kč with a 14-day report turnaround and seven-days-a-week availability allows neurologists and epileptologists to arrange pre-surgical evaluation efficiently.
spine-mri
MRI Spine — One Segment (MR jednoho úseku páteře)
Klinika JL performs MRI of the cervical, lumbar and sacral spine on a Philips 3 Tesla scanner, producing high-resolution images of intervertebral discs, the spinal cord, nerve roots and vertebral bodies. Each self-pay booking covers one spinal segment at 9,000 Kč. The 3 Tesla field strength improves conspicuity of disc material pressing on nerve roots and subtle cord signal changes compared with lower-field systems — important for planning surgery or epidural procedures. Thoracic spine is not available at this clinic. Results are reported digitally; the clinic is open seven days a week until 21:00 for urgent orthopaedic and neurology referrals.
abdomen-mri
MRI Kidneys and Pancreas (MR ledvin / slinivky)
MRI of the kidneys and pancreas at Klinika JL provides detailed cross-sectional imaging of the renal parenchyma, adrenal glands and pancreatic body and tail without radiation, using gadolinium contrast on the Philips 3 Tesla scanner. Renal cell carcinoma, angiomyolipomas, complex cysts (Bosniak grading) and pancreatic ductal adenocarcinoma, IPMN and neuroendocrine tumours are reliably characterised. Three-to-four hour fasting is required. The 3 Tesla field strength provides diffusion-weighted imaging that improves small-lesion detection in both organs.
Locations
1 location